Abbreviation |
: DQE |
Long Form |
: detective quantum efficiency |
|
No. |
Year |
Title |
Co-occurring Abbreviation |
1 |
2020 |
Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study. |
CdTe, Si |
2 |
2020 |
Electron-event representation data enable efficient cryoEM file storage with full preservation of spatial and temporal resolution. |
DDD, EER |
3 |
2020 |
Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation. |
AMFPI, BI |
4 |
2020 |
Low-dose megavoltage cone-beam computed tomography using a novel multi-layer imager (MLI). |
CNR, FFF, GOS, HU, MLI, MVCBCT |
5 |
2020 |
Physical characterization of a novel wireless DRX Plus 3543C using both a carbon nano tube (CNT) mobile x-ray system and a traditional x-ray system. |
CNT, FE, MTF, NNPS |
6 |
2019 |
An experimental method to directly measure DQE[Formula: see text] at k = 0 for 2D x-ray imaging systems. |
MTF, NPS |
7 |
2019 |
Cascaded systems analysis of a-Se/a-Si and a-InGaZnO TFT passive and active pixel sensors for tomosynthesis. |
a-IGZO, a-Se, a-Si, APS, DBT, FFDM, MTF, NPS, PPS, TFT |
8 |
2019 |
Characterizing a novel scintillating glass for application to megavoltage cone-beam computed tomography. |
CBCT, EPID, kV, MTF, MV, NNPS, NPS, OBI, SDNR |
9 |
2019 |
Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries. |
BI, FI, I-FPDs, MTF, NPS |
10 |
2019 |
Influence of silicon wall thickness on the performance of structured CsI(Tl) scintillation screen based on oxidized silicon micropore array template in X-ray imaging. |
BLO, LO, MTF |
11 |
2019 |
Nonstationary model of oblique x-ray incidence in amorphous selenium detectors: II. Transfer functions. |
a-Se, MTF, NGT, NNPS, NPS, OTF, PA, ROI |
12 |
2019 |
Objective assessment of task performance: a comparison of two FFDM detectors using an anthropomorphic breast phantom. |
a-Se |
13 |
2019 |
Quantitative analysis of effects of the grid specifications on the quality of digital radiography images. |
DR, MTF, NNPS, PMMA |
14 |
2019 |
Simulation and design of folded perovskite x-ray detectors. |
--- |
15 |
2019 |
Throughput and resolution with a next-generation direct electron detector. |
cryo-EM, DEDs, VPP |
16 |
2018 |
A framework for performance characterization of energy-resolving photon-counting detectors. |
NEQ |
17 |
2018 |
A high DQE water-equivalent EPID employing an array of plastic-scintillating fibers for simultaneous imaging and dosimetry in radiotherapy. |
EPID, MC, MTF, NPS |
18 |
2018 |
A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance. |
EPID, MTF, NRMSE |
19 |
2018 |
Accuracy validation of incident photon fluence on detective quantum efficiency in mammography. |
IEC, MTF, NPS |
20 |
2018 |
Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis. |
DBT, MTF, NNPS |
21 |
2018 |
Characterization of photon-counting multislit breast tomosynthesis. |
ASF, MTF |
22 |
2018 |
High-precision noise power spectrum measurements in digital radiography imaging. |
NPS |
23 |
2018 |
Impact of anti-charge sharing on the zero-frequency detective quantum efficiency of CdTe-based photon counting detector system: cascaded systems analysis and experimental validation. |
ACS, CdTe, PCD |
24 |
2018 |
Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance. |
CBCT, FPDs, MTF, NEQ, NPS |
25 |
2018 |
Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities. |
CBCT, CMOS, FPD, MTF |
26 |
2018 |
Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors. |
--- |
27 |
2018 |
Report of AAPM Task Group 162: Software for planar image quality metrology. |
eDQE, MTF, NPS |
28 |
2018 |
Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging. |
MTFs, Tl |
29 |
2018 |
Technical Note: Comparison of first- and second-generation photon-counting slit-scanning tomosynthesis systems. |
ASF, DBT, MTF |
30 |
2018 |
Tutorial on X-ray photon counting detector characterization. |
CdTe, CTF, LSF, MTF, NPS, PSF |
31 |
2017 |
A CMOS-based high resolution fluoroscope (HRF) detector prototype with 49.5 mum pixels for use in endovascular image guided interventions (EIGI). |
EIGI, EIGIs, HRF, HRF, MTF, NEQ, NPS, QDE |
32 |
2017 |
A comprehensive model for x-ray projection imaging system efficiency and image quality characterization in the presence of scattered radiation. |
BTF, CD, DQEsys, eDQE, gDQE, MC, MTF, PSF, SDNR |
33 |
2017 |
A novel multilayer MV imager computational model for component optimization. |
MLI, MTF, MV, NPS, NRMSE |
34 |
2017 |
Detective quantum efficiency (DQE) in PET scanners: A simulation study. |
Al, MC, MLE, MTF, NNPS, PET, STIR, TLC |
35 |
2017 |
MTF and DQE enhancement using an apodized-aperture x-ray detector design. |
AAP, MTF, NPS |
36 |
2017 |
Super-resolution imaging in a multiple layer EPID. |
CNR, EPID, MV, PSF, SR |
37 |
2017 |
Technical characterization of five x-ray detectors for paediatric radiography applications. |
CR, DAK, FPD, MTF, NIP, NPS, PIP |
38 |
2017 |
Technical Note: Detective quantum efficiency simulation of a-Se imaging detectors using ARTEMIS. |
--- |
39 |
2017 |
Three-dimensional cascaded system analysis of a 50 m pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis. |
APS, CMOS, DBT, FBP, MTF, NNPS, PPS, TFT |
40 |
2016 |
A comprehensive model for quantum noise characterization in digital mammography. |
MTF, NPS |
41 |
2016 |
A novel EPID design for enhanced contrast and detective quantum efficiency. |
CNR, EPID, MTF, NNPS |
42 |
2016 |
A novel method for the optimization of positron emission tomography scanners imaging performance. |
Al, MLE, MTF, NNPS, PET, STIR, TLC, USA |
43 |
2016 |
CHARACTERISING THE EOS SLOT-SCANNING SYSTEM WITH THE EFFECTIVE DETECTIVE QUANTUM EFFICIENCY. |
eDQE |
44 |
2016 |
Detective quantum efficiency for photon-counting hybrid pixel detectors in the tender X-ray domain: application to Medipix3RX. |
--- |
45 |
2016 |
In silico investigation of factors affecting the MV imaging performance of a novel water-equivalent EPID. |
EPID, MC, MTF, NPS, PSFs |
46 |
2016 |
Monte-Carlo simulation of a slot-scanning digital mammography system for tomosynthesis. |
DBT, FFDM, MTF, NPS |
47 |
2016 |
NPWE model observer as a validated alternative for contrast detail analysis of digital detectors in general radiography. |
CD, CR, DAK, DR, MTF, NNPS, NPWE |
48 |
2016 |
Performance evaluation of a retrofit digital detector-based mammography system. |
PMMA |
49 |
2016 |
Processing of Cryo-EM Movie Data. |
DDD |
50 |
2016 |
Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs. |
EPIDs, MTF, NPS, QA |
51 |
2015 |
50 mum pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis. |
APSs, DBT, MGD, MTF, NPS, SNRi |
52 |
2015 |
Comparative investigation of the detective quantum efficiency of direct and indirect conversion detector technologies in dedicated breast CT. |
bCT, CsI, GOS, MTF, NPS |
53 |
2015 |
Detective quantum efficiency of photon-counting x-ray detectors. |
CSA, PDF, SPC |
54 |
2015 |
Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications. |
ASICs, CdTe, CdZnTe, CT, FOV, FWHM, NDT, OCR |
55 |
2015 |
FEI's direct electron detector developments: Embarking on a revolution in cryo-TEM. |
--- |
56 |
2015 |
Filtration to reduce paediatric dose for a linear slot-scanning digital X-ray machine. |
--- |
57 |
2015 |
Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization. |
APS, CMOS, CNR, DBT, LFW, MGD |
58 |
2015 |
Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors. |
IEC, MTF |
59 |
2014 |
Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis. |
a-IGZO TFT, APS, DBT, OPD |
60 |
2014 |
AXIS: an instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF. |
ARC, ICF, NIF |
61 |
2014 |
Cascaded systems analysis of photon counting detectors. |
EIDs, MTF, NPS, PCDs |
62 |
2014 |
Comparison of gamma (Anger) camera systems in terms of detective quantum efficiency using Monte Carlo simulation. |
--- |
63 |
2014 |
Comparison of optimal performance at 300keV of three direct electron detectors for use in low dose electron microscopy. |
MTF |
64 |
2014 |
Experimental and theoretical performance analysis for a CMOS-based high resolution image detector. |
INEE, MTF, NPS |
65 |
2014 |
Free software for performing physical analysis of systems for digital radiography and mammography. |
MTF, NPS |
66 |
2014 |
Investigation of measurement accuracy of factors used for detective quantum efficiency measurement in digital radiography. |
DR, MTF, NNPS |
67 |
2014 |
Monte Carlo simulation of a quantum noise limited erenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging. |
AMFPI, EPIDs, kV-CBCT, QE |
68 |
2014 |
Occupational and patient exposure as well as image quality for full spine examinations with the EOS imaging system. |
EOS |
69 |
2014 |
Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique. |
AMFPIs, CNR, MVCBCT |
70 |
2014 |
Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques. |
AMFPIs |
71 |
2014 |
Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging. |
APSs, FPIs |
72 |
2014 |
Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function. |
MTF |
73 |
2014 |
Rapid Monte Carlo simulation of detector DQE(f). |
MSE, NPS, SNR |
74 |
2014 |
The effect of amorphous selenium detector thickness on dual-energy digital breast imaging. |
a-Se, CE, CLSM, DBT, DM, dSe, FBP, FPI, QDE |
75 |
2013 |
Accuracy validation of incident photon fluence on DQE for various measurement conditions and X-ray units. |
IEC |
76 |
2013 |
Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions. |
CSA |
77 |
2013 |
Characterization of a clinical unit for digital radiography based on irradiation side sampling technology. |
CsI, GOS, ISS, MTF, NPS |
78 |
2013 |
DQE of wireless digital detectors: comparative performance with differing filtration schemes. |
MTF, NNPS |
79 |
2013 |
Effective detective quantum efficiency for two mammography systems: measurement and comparison against established metrics. |
eDQE, FOMs, MTF, PMMA, SdNR, T/F |
80 |
2013 |
Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics. |
FPD, GDQE, GMTF, GNNPS, MAF, MTF |
81 |
2013 |
Influence of electron dose rate on electron counting images recorded with the K2 camera. |
--- |
82 |
2013 |
Investigation of image lag and modulation transfer function in fluoroscopy images obtained with a dynamic flat-panel detector. |
FPD, MTF, NPS |
83 |
2013 |
Quantitative characterization of electron detectors for transmission electron microscopy. |
MTF, TEM |
84 |
2013 |
Quantitative image quality measurements of a digital breast tomosynthesis system. |
DAK, DBT, FFT, MTF, NPS, STP |
85 |
2013 |
The detective quantum efficiency of photon-counting x-ray detectors using cascaded-systems analyses. |
CSA, SPC |
86 |
2012 |
A comparison of digital radiography systems in terms of effective detective quantum efficiency. |
eDQE, IDQE, MTF, NNPS |
87 |
2012 |
A forward bias method for lag correction of an a-Si flat panel detector. |
CBCT, FP, MTF |
88 |
2012 |
Characterization of the effects of the FineView algorithm for full field digital mammography. |
DAK, MTF, NNPS |
89 |
2012 |
Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers. |
--- |
90 |
2012 |
Detective Quantum Efficiency of a CsI-CMOS X-ray Detector for Breast Tomosynthesis Operating in High Dynamic Range and High Sensitivity Modes. |
HDR, hs |
91 |
2012 |
Image-quality assessment method for digital phase-contrast imaging based on two-dimensional power spectral analysis. |
NEQ, SIDF |
92 |
2012 |
Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models. |
ESAK |
93 |
2012 |
Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers. |
AMFPI, EPIDs, MV, MV-CBCT, QE |
94 |
2012 |
Physical evaluation of a needle photostimulable phosphor based CR mammography system. |
a-Se, CR, MGD, MTF, NNPS, SdNR |
95 |
2012 |
Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography. |
CR, NNPS, NPS |
96 |
2012 |
Sci-Fri PM: Delivery - 10: Megavoltage x-ray imaging detector based on cerenkov effect. |
AMFPI, EPID, MV |
97 |
2012 |
Spectral analysis of fundamental signal and noise performances in photoconductors for mammography. |
--- |
98 |
2012 |
The use of a figure-of-merit (FOM) for optimisation in digital mammography: a literature review. |
CNR, FOM, SNR |
99 |
2012 |
WE-C-217BCD-11: Coupled Radiative and Optical Geant4 Simulation of MV EPIDs Based on Thick Pixelated Scintillating Crystals. |
kV, MTF, MV |
100 |
2011 |
A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. |
CBCT, MSK, MTF |
|