A Search Service for Abbreviation / Long Form

■ Search Result - Abbreviation : FWHM

Search Conditions:
Search Keyword : FWHM
Search Method : Exact match.
Research Area:

Results:  
Abbreviation: FWHM
Appearance Frequency: 1288 time(s)
Long forms: 22

Display Settings:
[Entries Per Page]
 per page
Page Control
Page: of
Long Form No. Long Form Research Area Co-occurring Abbreviation PubMed/MEDLINE Info. (Year, Title)
full width at half maximum
(1257 times)
Biophysics
(368 times)
PET (65 times)
PL (47 times)
PSF (40 times)
1975 Effect of positron range on spatial resolution.
full width at half maximum intensity
(5 times)
Biophysics
(2 times)
CMR (1 time)
FTHM (1 time)
LVM (1 time)
1996 Measured electron energy and angular distributions from clinical accelerators.
full width at half maximum resolution
(5 times)
Radiology
(2 times)
3-MMC (1 time)
4-MEC (1 time)
DLC (1 time)
1980 Quantitation in positron emission computed tomography: 3 Effect of sampling.
full spectrum width at half maximum
(2 times)
Optics and Photonics
(1 time)
LD (1 time)
MLR (1 time)
NPE (1 time)
2010 [Study of spatially resolved hyperspectral scattering images for assessing beef quality characteristics].
full width at half-maximal
(2 times)
Vascular Diseases
(1 time)
CMR (1 time)
LGE (1 time)
MIR (1 time)
1994 The ECAT EXACT HR: performance of a new high resolution positron scanner.
films, while the beam profiles
(1 time)
Biophysics
(1 time)
MP512 (1 time)
SBRT (1 time)
SRS (1 time)
2014 A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512.
finite linewidth of 0.02 cm(-1)
(1 time)
Ophthalmology
(1 time)
--- 1994 Spectral control of an alexandrite laser for an airborne water-vapor differential absorption lidar system.
first and automatic shimming and water linewidth
(1 time)
Biomedical Engineering
(1 time)
MRS (1 time)
SNR (1 time)
2006 Can we use 1H MRS shimming values to obtain 31P spectra?
fluorescence width at half maximum
(1 time)
Molecular Biology
(1 time)
--- 2005 Investigation of thermal stability and spectroscopic properties in Er3+/Yb3+-codoped TeO2-Li2O-B2O3-GeO2 glasses.
10  focal spot with a diffraction-limited spot size
(1 time)
Ophthalmology
(1 time)
--- 1996 Diffractive lens fabricated with mostly zeroth-order gratings.
11  frequency width at half-maximum
(1 time)
Biophysics
(1 time)
FTIR (1 time)
2007 Structure-property relationships in major ampullate spider silk as deduced from polarized FTIR spectroscopy.
12  full spatial width at half-maximal fluorescence
(1 time)
Biophysics
(1 time)
--- 1999 Ca2+ sparks in embryonic mouse skeletal muscle selectively deficient in dihydropyridine receptor alpha1S or beta1a subunits.
13  full width at half intensity maximum
(1 time)
General Surgery
(1 time)
LIF (1 time)
LIFRS (1 time)
2005 Tooth caries detection by curve fitting of laser-induced fluorescence emission: a comparative evaluation with reflectance spectroscopy.
14  full width at half maximum of the emission
(1 time)
Spectrometry, Fluorescence
(1 time)
CMC (1 time)
MDCK (1 time)
PLQY (1 time)
2012 Microwave-assisted aqueous synthesis of highly luminescent carboxymethyl chitosan-coated CdTe/CdS quantum dots as fluorescent probe for live cell imaging.
15  full width at half maximum time-bandwidth product Deltat
(1 time)
Medicine
(1 time)
FEL (1 time)
2000 Formation of low time-bandwidth product, single-sided exponential optical pulses in free-electron laser oscillators
16  full-width at half-maximum of the primary phosphate band
(1 time)
Metabolism
(1 time)
AMF (1 time)
2013 Raman spectroscopy demonstrates Amifostine induced preservation of bone mineralization patterns in the irradiated murine mandible.
17  full-width half-maximum wavelength
(1 time)
Ophthalmology
(1 time)
--- 1993 Dispersion compensation for an integrated optic grating coupler utilizing a transmission volume hologram.
18  full-width-at-half- maximum value
(1 time)
Biophysics
(1 time)
GE (1 time)
MDCT (1 time)
2012 SU-E-I-42: Measurement of X-Ray Beam Width and Geometric Efficiency in MDCT Using Radiochromic Films.
19  full-width-at-half-maximum technique
(1 time)
Cardiology
(1 time)
CE-CMR (1 time)
ICC (1 time)
MANUAL (1 time)
2009 Rapid and accurate determination of relative infarct size in humans using contrast-enhanced magnetic resonance imaging.
20  FullWidthHalfMaximum
(1 time)
Chemistry Techniques, Analytical
(1 time)
C-T (1 time)
VLS (1 time)
2015 [Development of Micro-Spectrometer with a Function of Timely Temperature Compensation].
21  high-flux, short-pulse X-ray beams with pulse lengths of 1-10 ps
(1 time)
Radiology
(1 time)
SRF (1 time)
2014 Generation of picosecond electron bunches in storage rings.
22  time-of-flight mass spectrometer and mass separation powers
(1 time)
Chemistry Techniques, Analytical
(1 time)
RF (1 time)
2017 Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping.